Systems by site / Corporate headquarters access control scope

System scope

Corporate headquarters access control scope

Corporate offices, headquarters floors and multi tenant commercial towers

Corporate headquarters access control scope, floor plan: reception glass doors, staff door, finance and HR room, server room terminal, comms room controller and fire stair doors Tap to open full size

What this system protects

A defined access control scope for corporate offices and headquarters buildings, written for a tenancy that occupies one or more floors of a commercial tower and needs a reception line, a server room, and a set of restricted departments controlled separately.

It is built on an ICT Protege WX controller in the comms room, ICT tSec card and phone readers at the doors, and Suprema fingerprint or face terminals only where a door needs biometrics. Protege hardware is supplied on order through our Kenyan distributor, and estates spread across several sites are quoted separately.

Four decisions shape it. All lock relays sit inside the locked controller cabinet rather than behind the reader, so a reader pulled off the wall in a public corridor does not release the door behind it. Readers talk to the controller over encrypted RS-485 or OSDP with Secure Channel rather than Wiegand, so credential data on the cable cannot be captured and replayed. Frameless glass doors at reception are clamped rather than drilled. And the rules run on the controller itself rather than a Windows PC, so doors keep working when a server is patched, restarted or infected.

It is set up to keep the doors working through power cuts, with battery backup sized for the door count, and to support data protection compliance: individual administrator accounts, a defined period for keeping access records, and a card or PIN option for anyone who declines biometric enrolment.

No prices appear on this site. Send us the floor plate and the door schedule and we quote the whole scope, including the power supplies, cabling and door hardware that a bare equipment list leaves out.

What this scope covers

  • Reception line and the doors behind it
  • Server room, comms room and any records store
  • Restricted departments controlled as their own access levels
  • Staff, contractor and visitor credentials managed from one place
  • After hours access recorded by door and by person

What is included

  • ICT tSec readers at each controlled door for cards and phones, with Suprema fingerprint or face terminals where a door needs biometrics
  • ICT Protege WX controller and door expansion hardware in a lockable cabinet in the comms room
  • All lock release relays inside the cabinet, never behind the reader
  • Encrypted RS-485 or OSDP Secure Channel wiring between readers and controller
  • Protege third-party reader licence for each Suprema terminal, where biometric doors are specified
  • Mobile credentials for staff who want them, cancelled in software the day someone leaves
  • Rules held on the controller, so doors keep working independently of any server
  • Electric locking hardware per leaf type, including clamps for frameless glass at reception
  • Dedicated power supplies with battery backup sized for the door count
  • Door position and request to exit devices where the door schedule requires them
  • Emergency break glass release on every controlled escape route door
  • Access level design by department, individual administrator accounts, administrator training and handover documentation
  • Hard or soft anti-passback on the doors that need it
  • Escape route doors unlock on a fire alarm signal from the fire panel output
  • Managed from a web browser, with no Windows server or database licence to buy

Equipment in this scope

The products this scope is built from. Quantities are set from your door schedule or site survey.

What is not included

Listed here so it does not appear as an extra cost later.

  • Civil work, coring, chasing and making good
  • Containment, conduit, trunking and trays
  • Structured cabling backbone and network switching outside the access control cabinet
  • Door leaves, frames and closers where existing hardware is not suitable
  • Turnstiles, speed gates and reception furniture, quoted separately once the entrance design is fixed
  • Fire alarm interface cabling on the fire panel side
  • Integration into an HR or directory system, scoped separately once we know the platform
  • Any recurring software licence or portal subscription, which is quoted separately and stated on its own line
  • Landlord fit out consents and after hours access charges

What you get at handover

When we install, this is what you receive before we call the job finished.

  • Every controlled door tested and commissioned, with a signed commissioning record
  • Door schedule, access level list and as installed layout drawing, with the model and serial number of every device
  • Administrator training for IT or facilities, and a short guide for reception
  • 12 months workmanship warranty on our installation from the date of commissioning, in addition to the manufacturer warranty on the equipment
  • Optional service and maintenance after the first year, quoted separately

What the quote assumes

If any of these do not match your site, tell us and the scope changes. None of them are dealbreakers, they change the quantity.

  • A comms room with mains power and cabinet space is available on the floor plate
  • Cable routes exist above the ceiling or in floor boxes to every controlled door
  • Doors are structurally sound and closers work, so a lock that must hold will hold
  • Escape route doors are identified on the drawings before the lock type is chosen
  • Staff data for enrolment is provided in one file rather than door by door
  • Work is done in normal hours, or an after hours rate is agreed before we start

What we will ask you

Have these ready and we can usually quote without a site visit.

  • How many doors, and how many floors do they sit on?
  • How many staff will hold a credential, and how often do they change?
  • Which departments need to be separated from the general staff level?
  • Is reception frameless glass, and is there a turnstile planned?
  • Where is the comms room the controller can live in, and is there spare cabinet space?
  • Do you want cards, phones, fingerprint, face, or a mix?
  • Do you need access records tied to HR joiners and leavers, and on which platform?
  • Who will hold the administrator account, IT or facilities?

Bidding on a tender?

  • Bidding on a tender that says 'or equivalent'? Send us the specification and we prepare the clause by clause response, highlighted datasheets and bill of quantities for the equipment we supply
  • No charge when the equipment is supplied through Urban Eye. Company documents, bid security and your installation pricing stay with you
  • Where a specification asks for a reader with a built in relay, the readers meet that clause. We wire the lock to the relay in the locked controller cabinet instead, which Suprema also recommends where security matters
  • Wiegand is available where a specification requires it. Encrypted OSDP over RS-485 is recommended and quoted as standard